Cluster Upgrade
Note
Please refer to the release notes for the upgrade steps of each version.
Get Binary
- Get the binary of the specified version. Obtain the code of the specified version from https://github.com/cubeFS/cubefs/releases, and compile to generate the binary.
Freeze the Cluster
$ cfs-cli cluster freeze true
- During the freeze period, new data partitions cannot be created for the volume, but it does not affect ongoing business processes.
Notes
- Confirm the startup configuration file and do not change important information such as the data directory and port in the configuration file.
- For other parameter modifications in the configuration file, refer to the configuration instructions, release notes, etc.
- Upgrade order of each component, refer to the corresponding version release notes
- If there are no special requirements, the components can generally be upgraded in the order of datanode->metanode->master->client.
Upgrade DataNode
The following describes the upgrade process for datanode.
- Stop the old datanode process.
- Start the new datanode process.
- After starting, check the node status. Upgrade the next machine after it is displayed as active.
$ cfs-cli datanode info 192.168.0.33:17310
[Data node info]
ID : 9
Address : 192.168.0.33:17310
Carry : 0.06612836801123345
Used ratio : 0.0034684352702178426
Used : 96 GB
Available : 27 TB
Total : 27 TB
Zone : default
IsActive : Active
Report time : 2020-07-27 10:23:20
Partition count : 16
Bad disks : []
Persist partitions : [2 3 5 7 8 10 11 12 13 14 15 16 17 18 19 20]
Upgrade MetaNode
Similar to DataNode.
Upgrade Master
- Stop the old master process.
- Start the new master process.
- Observe whether the monitoring is normal.
- Check whether the corresponding raft status of the master is normal.
- As follows, check whether the commit corresponding to the restarted master ID is consistent with other replicas, and whether the raft has a leader.
curl 192.168.0.1:17010/get/raftStatus | python -m json.tool
{
"code": 0,
"data": {
"AppQueue": 0,
"Applied": 25168073,
"Commit": 25168074,
"ID": 1,
"Index": 25168074,
"Leader": 2,
"NodeID": 2,
"Replicas": {
"1": {
"Active": true,
"Commit": 25168074,
"Match": 25168074,
"Next": 25168075,
},
"2": {
"Active": true,
"Commit": 25168074,
"Match": 25168074,
"Next": 25168075,
"Paused": false,
},
"3": {
"Active": true,
"Commit": 25168074,
"Match": 25168074,
"Next": 25168075,
}
},
"RestoringSnapshot": false,
"State": "StateLeader",
"Stopped": false,
"Term": 292,
"Vote": 2
},
"msg": "success"
}
Upgrade Client
- Stop business read and write operations.
- Unmount the mount point.
- If the following error occurs, execute
umount -l mount point
.
- If the following error occurs, execute
umount: /xxx/mnt: target is busy.
(In some cases useful info about processes that use
the device is found by lsof(8) or fuser(1)
- If the client process exists, stop it.
- Start the new client process. Use
df -h
to check whether the upgrade is successful.